DORMAN Engine - Maintenance schedule article

SANDBY DUTY CHECK LIST

STANDBY DUTY
MAINTENANCE
OPERATION TO BE
PERFORMED
SYSTEM OPERATION DESCRIPTION

PERIOD

DAILY WEEKLY MONTHLY 6 MONTHLY ANNUALY
OR
250 HOURS
Lubricatoin Check For leaks
Engine oil level

*
*

*
*

*
*

*
*

*
*

Change Full flow filter
Engine oil

-
-

-
-

-
-

*
*

*
*

Clean Crankcase breather

-

-

-

*

-

Cooling Check

For leaks
For radiator air restriction
Operation of cooling sytem
& immersion heater
Hoses & connections
Coolant level
Antifreeze & inhibitor %age
Belt condition & tension

*

*
*

*

*
*

*

*
*
*
*
*
*
*

*
*
*
*
*
*
*
*

*
*
*
*
*
*
*
*

Grease Fan hub & jocky pulley brg.

-

-

-

*

*

Check Drive pulley & water pump

-

-

-

*

*

Change Coolant

Every 12 months

Clean Cooling system

Every 12 months

Air Check For leaks
Air cleaner restriction
Pipes & connections

-


*

*
*

*
*
*

*
*
*

Clean Crankcase breather

-

-

*

*

*

Change Air cleaner element

-

-

-

-

*

Fuel Check For leaks
Fuel level
Injector linkage
Fuel lines & connections
Fuel lift pump

*

*
*

*
*


*

-

-

Drain Sediment from tanks

-

-

*

-

-

Change Fuel filters

-

-

-

*

*

Check Injectors

Every 2 years

Adjust Bridge pieces & valves

-

-

-

-

*

Exhaust Check For leaks
For exhaust restrictions

-

*
*

*
*

*
*

Electrical Check

Battery charging alternar
betl condition & tension
Battery electrolyte
Specific gravity
Protection switches & alarms
Starter bolts & terminals

-



*

*

*

*
*
*

*

*
*
*

*

*
*
*
*

Engine
relate
Check For unusual vibration
Tightness of mountings

-

*

*

*

*
*

Clean Engine

-

-

-

-

*

NOTE: All bolts, hose clips, terminal connections, pipes and joints, should be check fo rtightness and leaks every 3 months, unless stated otherwise.




Service

ชนิดและขนาดของแมคเนติกคอนแทกเตอร์
แจ้งเครื่องกำเนิดไฟฟ้าขัดข้อง
RGAM - ALARMS INFORMATION article
MAINTENANCE - LIGHT LOAD OPERATION article
EXTENDING TURBOCHARGER LIFE article
DEERE ENGINE SERIAL NUMBER PLATE INFORMATION article
A15-MAINTENANCE REQUESTED ALARM RESETING article
BLEEDING THE FUEL SYSTEM : 2.9L/4039/4.5/6.8L article



Copyright © 2010 All Rights Reserved.